Pipe Cooling

 

Overview

Define the Pipe Cooling which reduces the heat of hydration. The user can model with buried pipe, and reduce the heat of hydration by water cooling. In this case, the heat exchange is through convection between the pipe surface and cooling water.

 

Methodology

                  

 

  

Name

Enter the name of  the pipe cooling.

Cooling Pipe Diameter

Enter the pipe diameter.  

Convection

Enter the Convection Coefficient..

Cooling Water Specific Heat

Enter the specific heat of cooling water.

Mass Density

Enter the density of cooling water.

Flow Rate

Enter the Unit Flow Rate.

Inlet Temp.

Enter the temperature of pipe inlet.

Time Function

Select the function to be applied to time.

 Global Time

The time applied to the time function is based on the total analysis time.

 Local Time

The time applied to the time function is based on the subcase time.

Thermal Load

Register the pipe cooling conditions to a desired thermal load set.  
The user may assign any name to the load set.